Intelligent Addressable Systems offer benefits in terms of speed of detection, identification of the location of fire and easier maintenance. Intelligent systems also offer tolerance to faults in the system wiring, which allows a single pair of wires to be used to connect up to 200 devices to the system, allowing cost savings in the wiring of large systems.
Conventional Fire Alarm System provides the earliest practicable fire detection and warning. This system consists of smoke or heat detectors at designated locations, to detect smoke or heat at the earliest during any outbreak of fire.
The Hybrid Fire Alarm System combines the capabilities of both Intelligent Addressable and Conventional Fire Alarm System.
Aspirating smoke detection is a technology that utilizes a centralized detector that continuously draws air into the detector from a sampling pipe network located within the protected area. Whether your application is dusty, dirty, wet, highly-ventilated, or has extreme temperatures, vibrations, or electromagnetic interferences, aspirating smoke and gas detection may be the solution for your difficult smoke detection needs.
Very Early Warning Smoke Detection is a technology that provides the ability to detect a fire in its incipient phase so that it can be investigated and controlled before it escalates causing damage, loss of life or assets and adversely impacting business continuity.
LINEAR HEAT SENSOR CABLE is also called as Linear Heat Detection Cable. LHS cable is made up of 2 conductors which are covered by heat sensitive polymers Linear Heat Sensor cable is a flexible, Durable and cost-effective fixed temperature fire detector, suitable for protecting a wide range of Commercial and industrial fire applications where spot-type heat detectors are unsuitable. Simple and easy- to-install, the LHS cable Contacts directly to the fire alarm panel initiating circuit. A short circuit along the LHS cable indicates a zone alarm condition. The LHS cable is available in a variety of operating temperatures and jackets.
The heat from a fire causes the LHS cable’s special insulation to melt at a specific temperature, allowing the two conductors to short together, thus creating an alarm condition on the fire control panel.
LPG PNG Gas Leak Detectors should be installed at commercial/industrial kitchens. Commercial kitchens like restaurants, food courts, and cafés are equipped with burners & stoves that use PNG (Pipeline Natural Gas) or LPG (Liquefied Petroleum Gas). Both LPG & PNG are highly flammable & combustible when ignited; a slight leak of these gases can cause a disaster if a proper detection system is not in place.
Therefore, we have developed a Gas Leak Detector that can sense LPG, PNG, and CNG & LNG. We provide solutions that can ensure that your premises are Fire Compliant & safe from any gas leaks. PESO, CE, ISI, and CCOE & Chief Fire Officer (CFO) certify the gas detectors. These gas detectors are manufactured in Mumbai, as we are the largest gas detector manufacturers in India. Our gas transmitters are available in flameproof (Explosion Proof) as well as weatherproof housing/enclosure.
Kitchen and Canteen areas of Industrial units, Commercial or residential premises, Hotels, Restaurants, Cafeterias etc
FM-200 is one of the most well-known and trusted clean agents in use today. This colorless, liquefied compressed gas is capable of extinguishing fires in just 10 seconds or less, making it the fastest-acting clean agent available. Its flexible design options make it suitable for many applications, including data centers.
When you install an FM-200 commercial fire suppression system, you’re choosing an eco-friendly fire suppressant that has an ozone depletion potential (ODP) of zero. It’s also safe to discharge FM-200 in occupied spaces and has small storage space requirements.
FK-5-1-12 protects thousands of facilities around the world against the risk of fire. The extinguishing agent, a substitute to the more widely recognized Halon 1301, has excellent fire extinguishing performance and other ideal characteristics. FK-5-1-12 clean agent requires significantly less cylinders as the synthetic agent is stored as a liquid .
Using EN standards for reference, there is a safety margin of over 70% between the typical design concentration and the NOAEL (No observed adverse effect limit)
Upon activation from an automatic detection system, the agent is designed using hydraulic flow calculation software to discharge and reach the adequate extinguishing concentration within 10 seconds for fast extinguishing, compared to the 60 or 120 second allowance given to Inert gases.
FK-5-1-12 is not subject to F-Gas regulation and has favored environmental properties
The INERGEN Gas Suppression System is a clean agent, non-toxic, non-corrosive, inert gas fire suppressant agent consisting of natural gases that extinguish a fire without causing harm to the people, assets or the environment.
INERGEN® IG-541 Gas Fire Suppression System is particularly well suited to suppressing fires in special hazards where an electrically non-conductive medium is essential or desirable, where clean-up of other agents presents a problem, or where the risk is usually occupied and requires a non-toxic agent.
When discharged into an area or room, a correctly designed clean agent INERGEN Fire Suppression System lowers the oxygen concentration below that supported by combustion.
INERGEN (IG-541) was introduced as an alternative to earlier gaseous fire suppression agents and is a compound of 3 naturally occurring inert gases that comprise our atmosphere. Argon (40%), Nitrogen (52%) and Carbon Dioxide (8%). These three gases do not support combustion (combined or separately).
INERGEN has zero Ozone Depleting Potential (ODP), zero Global Warming Potential (GWP) and doesn’t contribute unique chemical compounds with extended atmospheric lifetimes as other Gaseous Fire Suppression Agents can.
The following lists special hazard applications that INERGEN IG-541 Gas Suppression systems are well suited to protect:
Carbon Dioxide Suppression Systems use CO2 which has a high rate of expansion to suppress fires quicklyCarbon Dioxide (CO2) Fire Suppression Systems
Another option for a fast acting fire suppressant is CO2. As an odorless, colorless, electrically non-conductive gas, it has a number of uses and has been approved for Class A, B and C fires. Carbon dioxide has a high rate of expansion, which allows for it to act quickly suppressing the fire.